webmail

CHEMICAL ANCHORS: INJECTION TYPE
EPX-5K 100% pure epoxy resin for threaded rod or rebar fixing
Volume 400 ml.

SANKO EPX-5K, it is specially formulated chemical anchor based on 100% pure epoxy resin, quick loading, no shrinking, and ideals for hot climate. The product can be stored even at temperatures above 30° C. SANKO EPX-5K has the strong bonding to the concrete and good performance in oversized holes. Application into wet concrete or diamond cored hole does not affect its performance.


APPLICATIONS:

• Generator foundation,
• Heavy duty machine,
• Jib crane,
• Automobile lift,
• Electrical power pole,
• Antenna tower,
• Floor slab connection,
• Wall and beam connections,
• Column connections,
• Structural repairing,
• Structural staircases,
• And etc.

USING THE CARTRIDGE:  
1. Unscrew the cap and take out the plug.
2. Pull piston back and place cartridge into gun. Check the ejection of resin and hardener.
3. Screw on mixing nozzle. Do not use the first few centimeters of mixture (until the color of mixture change to be steady gray color).

INSTALLATION INSTRUCTIONS:

1. Drill the hole.
2. Thoroughly clean the hole to remove the dust by using a wire brush and a puffer.
3. Apply nozzle to the hole. Work from the bottom outwards until it fills approximately half of the hole.
4. Insert steel bar into the resin. Slowly rotate it by hand.

5. Wait until it is full curing (see table).
 
CURING TIME:

 Temperature
Approx.
curing start
Approx.
full curing time
°C
°F
5
41

30 min

        8 hrs
10
50

15 min

        6 hrs 30 min
15
59

12 min

        5 hrs
20
68

10 min

        3 hrs 30 min
25
77

6 min

        2 hrs 45 min
30
86

4 min

        2 hrs
35
95

3 min

        1 hrs 45 min

 

SANKO EPX-5K INSTALLATION TABLE
WITH REINFORCING BAR (REBAR)

Norminal diameter (d): mm
DB8
DB10
 DB12
DB16
DB20
DB25
DB32
DB40
Minimum base material thickness (hmin): mm
120
150
180
240
300
360
480
600
Standard embedment depth (hnon): mm
80
100
120
160
200
250
320
400
Hole depth (hdep): mm
80
100
120
160
200
250
320
400
Drill bit diameter (do): mm
10
12
14
18
22
28
38
45
Minimum edge distance (Cmin): mm
40
50
60
80
100
125
160
200
Minimum anchor spacing (Smin): mm
40
50
60
80
100
125
160
200
Ultimate tension load (Nu,avg): kN
20
35
50
95
150
 
Allowance tension working load (Nall): kN
4
7
10
19
30
 
Filling volume :ml
7.5
11.3
15
22.6
37.7
 
Trigger No.
 1
1.5
 2
 3
 5
 
Number of fixing per cartridge (approx.): nos            

SANKO EPX-5K INSTALLATION TABLE
WITH
FOR THREADED RODS
(Steel Gr. 5.8 and concrete C20/25)

Norminal diameter (d): mm
 M8
 M10
 M12
 M16
M20
M24
M30
M32
Anchor length (L): mm
100
125
150
200
250
300
Minimum base material thickness (hmin): mm
120
150
180
240
300
360
Standard embedment depth (hnon): mm
80
100
120
160
200
240
Hole depth (hdep): mm
80
100
120
160
200
240
Drill bit diameter (do): mm
10
12
14
18
22
26
Minimum edge distance (Cmin): mm
40
50
60
80
100
120
Minimum anchor spacing (Smin): mm
40
50
60
80
100
120
Maximum fixturethickness (FT,max): mm
10
12
15
20
25
30
Hexagon nut spanner width (sw): mm
13
17
19
24
30
36
Ultimate tension load (Nu,avg): kN
20
35
50
95
150
200
Allowance tension working load (Nall): kN
4
7
10
19
30
40
Filling volume :ml
7.5
11.3
15
22.6
37.7
60.3
Trigger No.
 1
1.5
 2
 3
 5
8
Number of fixing per cartridge (approx.): nos
48
 32
 24
 16
 9
6

 

Product
Code
 Nominal
Dia.
 Overall
Lenght
(mm)
Embedment
Depth
(mm)
 Drill Bit
Dia.
(mm)
Max. Fixture
Thickness
(mm)

Grade of
Material

TR-08100-58
M8
100
min. 55
rec. 80*
10
10
Gr. 5.8
TR-10125-58
M10
125
min. 70
rec. 100*
12
12
Gr. 5.8
TR-12150-58
M12
150
min. 85
rec. 120*
14
15
Gr. 5.8
TR-16200-58
M16
200
min. 115
rec. 160*
18
20
Gr. 5.8
TR-20250-58
M20
250
min. 140
rec. 200*
22
25
Gr. 5.8
TR-24300-58
M24
300
min. 170
rec. 240*
26
30
Gr. 5.8
TR-08100-A2
M8
100
min. 55
rec. 80*
10
10
A2-70W
(SUS304)
TR-10125-A2
M10
125
min. 70
rec. 100*
12
12
A2-70W
(SUS304)
TR-12150-A2
M12
150
min. 85
rec. 120*
14
15
A2-70W
(SUS304)
TR-16200-A2
M16
200
min. 115*
rec. 160
18
20
A2-70W
(SUS304)
TR-20250-A2
M20
250
min. 140
rec. 200*
22
25
A2-70W
(SUS304)
TR-24300-A2
M24
300
min. 170
rec. 240*
26
30
A2-70W
(SUS304)

* Recommend of embedment depth.

 
 